ACS150 Ratings, Types, Voltages and Construction
Type CodeIn column 4 on the right is the unique reference number that clearly identifies the drive by power rating and frame size. Once the type code is selected, the frame size (column 5) can be used to determine the drives dimensions (as above). VoltagesThe ACS150 is available in two voltage ranges:
Insert either "2" or "4", depending on your chosen voltage, into the type code shown on the right. Construction"01X" and "03X" within the type code varies depending on the rive phase and EMC filtering. Choose from the one you require below:
DimensionsThe left hand drive is a cabinet-mounted drive (UL open) and the right is a wall-mounted drive (NEMA 1). |
|
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||

| Frame Size | IP20 UL open |
NEMA 1 |
|||||||||
| H1 mm | H2 mm | H3 mm | W mm | D mm | Weight Kg | H4 mm | H5 mm | W mm | D mm | Weight Kg | |
| R0 | 169 | 202 | 239 | 70 | 142 | 1.1 | 257 | 280 | 70 | 142 | 1.5 |
| R1 | 169 | 202 | 239 | 70 | 142 | 1.3 | 257 | 280 | 70 | 142 | 1.5 |
| R2 | 169 | 202 | 239 | 105 | 142 | 1.5 | 257 | 282 | 105 | 142 | 1.5 |
- H1 = Height without fastenings and clamping plate
- H2 = height with fastenings but without clamping plate
- H3 = Height with fastenings and clamping plate
- H4 = Height with fastenings and NEMA 1 connection box
- H5 = Height with fastenings, NEMA 1 connection box and hood
- W = Width
- D = Depth