ABB Drives ACS 350 Dimensions
 

Type Code

ACS350 - 01E - 02A4 - 2 + B061

This is the unique reference number (shown above and in column 4 right) that clearly identifies your drive by power rating and frame size.  One you have selected the type code, the frame size (column 5) can be used to determine the drive dimensions, shown below.

Voltages

The ACS350 is available in two voltage ranges:

  • 2 = 200 - 240 V
  • 4 = 380 - 480 V

Insert either "2" or "4", depending on your chosen voltage, into the type code shown above.
 

Construction

"O1E" within the type code (above) varies depending on the drive phase and EMC filtering:

  • 01 =  1 - phase
  • 03 = 3 - phase

E = EMC filter connected, 50 Hz frequency
U = EMC filter disconnected, 60 Hz frequency.  (In case the filter is required it can simply be connected)

 
Ratings Type Code Frame Size
Pn kW Pn hp I2n A
1 phase supply voltage 200 - 240 V units
0.37 0.5 2.4 ACS350-01X-02A4-2 R0
0.75 1 4.7 ACS350-01X-04A7-2 R1
1.1 1.5 6.7 ACS350-01X-06A7-2 R1
1.5 2 7.5 ACS350-01X-07A5-2 R2
2.2 3 9.8 ACS350-01X-09A8-2 R2
3 phase supply voltage 200 - 240 V units
0.37 0.5 2.4 ACS350-03X-02A4-2 R0
0.55 0.75 3.5 ACS350-03X-03A5-2 R0
0.75 1 4.7 ACS350-03X-04A7-2 R1
1.1 1.5 6.7 ACS350-03X-06A7-2 R1
1.5 2 7.5 ACS350-03X-07A5-2 R1
2.2 3 9.8 ACS350-03X-09A8-2 R2
3 4 13.3 ACS350-03X-13A3-2 R2
4 5 17.6 ACS350-03X-17A6-2 R2
3-phase supply voltage 380 - 480 V units
0.37 0.5 1.2 ACS350-03X-01A2-4 R0
0.55 0.75 1.9 ACS350-03X-01A9-4 R0
0.75 1 2.4 ACS350-03X-02A4-4 R0
1.1 1.5 3.3 ACS350-03X-03A3-4 R1
1.5 2 4.1 ACS350-03X-04A1-4 R1
2.2 3 5.6 ACS350-03X-05A6-4 R1
3 4 7.3 ACS350-03X-07A3-4 R1
4 5 8.8 ACS350-03X-08A8-4 R1
5.5 7.5 12.5 ACS350-03X-12A5-4 R3
7.5 10 15.6 ACS350-03X-15A6-4 R3

Frame Size

IP20 UL Open

NEMA 1

H1 mm H2 mm H3 mm W mm D mm Weight kg H4 mm H5 mm W mm D mm Weight kg
R0 169 202 239 70 162 1.1 257 280 70 169 1.5
R1 169 202 239 70 162 1.3 257 282 70 169 1.7
R2 169 202 239 105 162 1.5 257 282 105 169 1.9
R3 169 202 236 169 169 2.5 260 299 169 177 3.1

  • H1 = height without fastenings and clamping plate
  • H2 = Height with fastenings but without clamping plate
  • H3 = Height with fastenings and clamping plate
  • H4 = Height with fastenings and connection box
  • H5 = Height with fastenings, connection box and hood
  • W = Width
  • D = Depth

Options

The options shown below are available within the ACS350 range.  Each has an associated 4 figure option code which is shown in the first column.  It is this code that replaces B061 in the type code above.  You can order as many options as required, simply by extending the code as necessary.

Selection Table
Protection class    
B061 NEMA 1  
Control panel    
J400 Assistant control panel ACS-CP-A
J404 Basic control panel ACS-CP-C
- Panel mounting kit ACS/H-CP-EXT
Potentiometer    
J402 Potentiometer MPOT-01
Fieldbus    
K451 DeviceNet FDNA-01
K454 PROFIBUS DP FPBA-01
K457 CANopen FCAN-01
K458 ModBus RTU FMBA-01
     
 

CSE Industrial Electrical Distributors; Email : - Tel:01628 529448; Fax:01628 810093;
Cable Enquiries Tel
: 01628 850024; Email :

Tel : International enquiries +44 (0)1628 529448, International Fax - +44 (0)1628 810093 , Tel : South UK - 023 8063 3055