Danfoss Type KPS Thermostat
KPS units are pressure-controlled switches. The position of the contacts depends on the pressure in the inlet connection and the set scale value. In this series, special attention has been given to meeting important demands for:
- a high level of enclosure,
- robust and compact construction,
- resistance to shock and vibration.
The KPS series covers most outdoor as well as indoor application requirements.
KPS pressure switches are suitable for use in alarm and regulation systems in factories, diesel plant, compressors, power stations and on board ship.
Approvals - EN 60 947-4-1 and EN 60 947-5-1
Ship Approvals - American Bureau of Shipping; Germanischer Lloyd, Germany Bureau Veritas, France. Includes thermostats with fixed sensor and pressure controls with armoured capillary tube.
1. Pressure Switches
Setting range |
Adjustable/ fixed differential [bar] |
Permissible operating pressure Pe (bar) |
Max. test pressure (bar) |
Pressure Connection | Order Code | Type |
| 0 - 2.5 | 0.1 | 6 | 6 | G 1/4 | 060-311066 | KPS 31 |
| 0 - 2.5 | 0.1 | 6 | 6 | G 3/8A | 060-310966 | KPS 31 |
| 0 - 3.5 | 0.2 | 10 | 10 | G 1/4 | 060-310466 | KPS 33 |
| 0 - 3.5 | 0.2 | 10 | 10 | G 3/8A | 060-310366 | KPS 33 |
| 0 - 8 | 0.4 - 1.5 | 12 | 12 | G 1/4 | 060-310566 | KPS 35 |
| 0 - 8 | 0.4 - 1.5 | 12 | 12 | G 3/8A | 060-310066 | KPS 35 |
| 0 - 8 | 0.4 | 12 | 12 | G 1/4 | 060-310866 | KPS 35 |
| 6 - 18 | 0.85 - 2.5 | 22 | 27 | G 1/4 | 060-310666 | KPS 37 |
| 6 - 18 | 0.85 - 2.5 | 22 | 27 | G 3/8 A | 060-310166 | KPS 37 |
| 10 - 35 | 2.0 - 6 | 45 | 53 | G 1/4 | 060-310766 | KPS 39 |
| 10 - 35 | 2.0 - 6 | 45 | 53 | G 3/8 A | 060-310266 | KPS 39 |
2. Pressure Switches for High Pressure and Strongly Pulsating Media
| Setting Range Pe (bar) |
Adjustable diff see also pdf | Permissible overpressure (bar) |
Max. test pressure (bar) |
Min. burst pressure (bar) |
Pressure Connection | Code No. | Type |
| 1 - 10 | 0.7 - 2.8 | 120 | 180 | 240 | G 1/4 | 060-312066 | KPS 43 |
| 4 - 40 | 2.2 - 11 | 120 | 180 | 240 | G 1/4 | 060-312166 | KPS 45 |
| 6 - 60 | 3.5 - 17 | 120 | 180 | 240 | G 1/4 | 060-312266 | KPS 47 |
Click for a complete Danfoss KPS Pressure Switch and Thermostat PDF.
Terminology
Range setting - The pressure range within which the unit will give a signal (contact changeover).
Differential - The difference between make pressure and break pressure (see pdf).
Permissible overpressure - The highest permanent or recurring pressure the unit can be loaded with.
Max. test pressure - The highest pressure the unit may be subjected to when, for example, testing the system for leakage. Therefore, this pressure must not occur as a recurring system pressure.
Min. bursting pressure - The pressure which the pressure-sensitive element will withstand without leaking.