Danfoss VLT 2800 Inverter Drives

The VLT® 2800 series is among the smallest multi purpose drives in the market. Designed for space saving side-by-side mounting. Choose to have it with e.g. Motor Coils, RFI filter, LC+1B filters.

The VLT 2800 is an advanced and versatile drive, easy to operate.

The quick menu includes all parameters basically needed for commissioning the drive. Offers fast installation and service

Product Range

0.55 – 18.5 kW
(3 phase 380 - 480 V ± 10 %; 50/60 Hz)
0.37 - 1.5 kW
(Combined 1 and 3 phase 200 - 240 V ± 10 %; 50/60 Hz)
2.2 - 3.7 kW
(3 phase 200 - 240 V ± 10 %; 50/60 Hz)

Variable output frequency between 0 and 1000 Hz

 

Danfoss VLT 2800

 

Need specialist advice on the Danfoss VLT 2800, VLT 5000 or VLT 6000 drives range?

Call or email Ray Hargreaves - CSE's Danfoss Consultant
on 023 8063 3055

Product safety

100 % short-circuit proof
100 % earth fault protection
Mains transient protection
Switching on input
Switching on output
Galvanic isolation
Designed according to EN 50178

Speed compensation precise stop

Better process control
Same stopping distance independent of initial motor speed

Precise stop

Interrupt controlled stop
Higher process repeatability
Well defined stopping

Counter stop

Accurate positioning
High frequency input (65 kHz)
24 V incremental encoder input
AB encoder input as option

Automatic motor tuning

Perfect match between motor and drive
Measures the stator resistance (RS)
Better shaft performance
Measurements done without applying torque
Checks for missing motor phases

Flexible mounting

Horizontal mounting
Vertical mounting
True side-by-side mounting
No derating
Also applies to modules
Temperature controlled fan

 

Cold plate technology

Reduced heating in cabinet
Denser installation
Higher enclosure class cabinets
Protection against:
- Dust
- Dirt
- Humidity
Heat dissipates through the back of the drive

Communication

DeviceNet
ModBus RTU
Profibus DP, optional

Fieldbus systems
Profibus DP 3 or 12 Mbit/s
Up to 127 nodes per installation
Homepage: www.profibus.com
DeviceNet Up to 500 kbit/s
Up to 64 nodes per installation
Homepage:www.odva.com

EMC filter and DC coils

Compliance with EMC Standards.
Built-in EN 55011 1A filter, 25 m screened cable.
No EMC disturbance.
EN 55011 1B filter available as module.
IT mains compatible version with RFI filter (up to 4 kW).
VLT 2880-2882 with RFI-switch.

Braking facilities

DC-braking - approx. 20% braking torque
AC-braking - approx. 20% braking torque
Dynamic braking
- Brake chopper built-in
- 160% braking torque
LCP2 Alpha numeric display, with copy function
MCT10 software


Danfoss VLT 2800 Series Options

VLT Type Typical Shaft Output (kW) Cont. Output current (Amps) @ 200 / 240V Input 50/60Hz IP20 Output 50/60Hz IP20
VLT 2803 0.37 2.2 240V, 1PH 240V, 3Ph
VLT 2805 0.55 3.2 240V, 1Ph 240V, 3Ph
VLT 2807 0.75 4.2 240V, 1Ph 240V, 3Ph
VLT 2811 1.10 6.0 240V, 1Ph 240V, 3Ph
VLT 2815 1.50 6.8 240V, 1Ph 240V, 3Ph
VLT Type Typical Shaft Output (kW) Cont. Output current (Amps) @ 380 / 415V Input 50/60Hz IP20 Output 50/60Hz IP20
VLT 2805 0.55 1.7 400V, 3Ph 400V, 3Ph
VLT 2807 0.75 2.1 400V, 3Ph 400V, 3Ph
VLT 2811 1.10 3.0 400V, 3Ph 400V, 3Ph
VLT 2815 1.50 3.7 400V, 3Ph 400V, 3Ph
VLT 2822 2.20 5.2 400V, 3Ph 400V, 3Ph
VLT 2830 3.00 7.0 400V, 3Ph 400V, 3Ph
VLT 2840 4.00 9.1 400V, 3Ph 400V, 3Ph
VLT 2855 5.50 12.0 400V, 3Ph 400V, 3Ph
VLT 2875 7.50 16.0 400V, 3Ph 400V, 3Ph
VLT 2880 11.00 24.0 400V, 3Ph 400V, 3Ph
VLT 2881 15.00 32.0 400V, 3Ph 400V, 3Ph
VLT 2882 18.50 37.5 400V, 3Ph 400V, 3Ph


VLT 2800 General Options

Part Number Description Used on VLT
175N0131 LCP2 Control Unit (IP.65) All
175Z0850 Remote mounting kit for LCP (includes 3m cable) All
175Z0929 Cable for LCP - 3 m (Also included in remote kit) All
175N0128 L O P (Local Operating Pad) - includes cable All
195N3113 Cable for 'DeviceNet' Connection All
195N1900 NEMA 1 Terminal Cover - Used on:

VLT 2803 - VLT 2815 (200 - 240V)
VLT 2805 - VLT 2815 (380 - 480V)



Call
195N1901 NEMA 1 Terminal Cover - Used on:

VLT 2822 - (200 - 240V)
VLT 2855 - VLT 2875 (380 - 480V)

 

Call

195N1902 NEMA 1 Terminal Cover - Used on:

VLT 2840 - (200 - 240V)
VLT 2855 - VLT 2875 (380 - 480V)

Call
195N3110 Motor coil module All
195N3103 1B RFI Filter Module All
195N3100 1B RFI / LC Filter Module - 4 amps
VLT 2803 - VLT 2805 (200 - 240V)
VLT 2805 - VLT 2815 (380 - 480V)
Call
195N3101 1B RFI / LC Filter Module - 9.1 amps
VLT 2807 - VLT 2815 (200 - 240V)
VLT 2822 - VTLT 2840 (380 - 480V)
Call
     
   

CSE Industrial Electrical Distributors; Email : - Tel:01628 529448; Fax:01628 810093;
Cable Enquiries Tel
: 01628 850024; Email :

Tel : International enquiries +44 (0)1628 529448, International Fax - +44 (0)1628 810093 , Tel : South UK - 023 8063 3055