Click to send us a

|
Click for printer friendly version |
 |

Danfoss High Power VLT Drives
The Smallest High Power Drive in its Class High efficiency
components and innovative designs make Danfoss VLT high power drives
extremely compact as well as simple to commission and operate.
Danfoss' high power drives are designed for side by side mounting in
standard Rittal cabinets.
Drive Flexibility
The modular design of the largest VLT drives provide maximum
flexibility to satisfy a wide range of application needs. The modular
drive inverters use the same power components as the stand alone drives,
reducing the number of spare parts required. In the event a repair is
necessary, the modular drives are designed to allow front door access to
all key components, minimising downtime.
 |
Need specialist advice on the Danfoss drives range?
Call or
email Ray Hargreaves - CSE's Danfoss Consultant
on 023 8063 3055 |
 |
Intelligent Cooling - Optimal Operation
Accessories allow for simple installation of IP00 high power VLT
series units in standard Rittal TS8 Enclosures. The kit is
available for 1800mm and 2000mm high enclosures. The minimum
depth of the enclosure is 500mm and the minimum width is 600mm for a
single frequency converter to be installed. Multiple drives
can be installed side by side in larger Rittal TS8 enclosures of the
same height.
Standardised Mounting
The options provide a mounting solution in standard Rittal TS8
enclosures where the customer can utilise the cooling attributes of
the high power drives. The design provides:
- A quick and simple installation with standard options saving
time and cost
- Utilisation of the internal fan of the drive to remove the
heat avoiding cost of additional fans in the Rittal enclosure
- Provides removal of up to 85% of the heat of the drive
through the duct work keeping internal components cooler
- Separate cooling air for the power components keeps the
interior of the drive clean of environmental contaminants
- Protection up to IP54 / NEMA12
- Uniformed look of installation if other components are
installed in standard enclosures
|
|
 |
Dedicated Filters Available
Dedicated filters are available to minimise potential
harmonic disturbance to other sensitive equipment that
are connected to the same power supply. Harmonic
disturbance is an issue to be considered with high power
applications. All Danfoss' drives have built-in DC
coils that minimises harmonic disturbance. If
additional filtering is specified Danfoss offers a full
line of filter solutions. |
|
 |
Fieldbus and Software Tools
Danfoss offers numerous serial communication options and
software programmes to support a wide range of applications.
Since all units in a VLT drive series utilise a common control
principle, the fieldbus or software tool used to control one VLT
drive can be used to control any VLT drive - regardless of power
or size:
- Features : menu structure and parameter structure are
similar throughout the VLT family
- Extending the set-up : commissioning and operation with
VLT high power drives is flawless, timesaving and simple
Lower Cost of Ownership
Space savings :
- The smallest high power drives on the market
- Zero side clearance required on the side of the
drives
- Front access only is required fro installation and
servicing
- Built-in options
Energy Savings :
High efficiency, typically better than 98% reduces
overall losses, power consumption and cooling
requirements
Optimised Operation :
IP00 / Chassis , IP21 / NEMA 1 and IP54 / NEMA 12
enclosures available as standard
Options to customise the drive :
Unique duct cooling solution along with IP00 /
Chassis enclosure provide a cost-effective solution to
provide customising of the drive
Time savings :
Same operating software and options for the complete
VLT product lines
Local control panels have the same, friendly,
familiar language
Maximising uptime :
- Lower component count reduces the number of
spare part variants
- Drives fully tested under load at the factory
- Factory designed, tested, certified options
increase drive reliability
Specifications
|
380 - 440 V |
441 - 500 V |
525 - 600 V |
690 V |
Normal OL
110% torque |
High OL
160% torque |
Normal OL
110% torque |
High OL
160% torque |
Normal OL
110% torque |
High OL
160% torque |
Normal OL
110% torque |
High OL
160% torque |
| In Amps |
Pn kW |
Ih Amps |
Ph kW |
In Amps |
Pn HP |
Ih Amps |
Ph HP |
In Amps |
Pn HP |
Ih Amps |
Ph HP |
In Amps |
Pn kW
|
Ih Amps |
Ph kW |
| 212 |
110 |
177 |
90 |
190 |
150 |
160 |
125 |
108 |
100 |
86 |
75 |
54 |
45 |
46 |
37 |
| 260 |
132 |
212 |
110 |
240 |
200 |
190 |
150 |
131 |
125 |
108 |
100 |
73 |
55 |
54 |
45 |
| 315 |
160 |
260 |
132 |
320 |
250 |
240 |
200 |
155 |
150 |
131 |
125 |
86 |
75 |
73 |
55 |
| 395 |
200 |
315 |
160 |
361 |
300 |
302 |
250 |
195 |
200 |
155 |
150 |
108 |
90 |
86 |
75 |
| 480 |
250 |
395 |
200 |
443 |
350 |
361 |
300 |
242 |
250 |
195 |
200 |
131 |
110 |
108 |
90 |
| 600 |
315 |
480 |
250 |
600 |
450 |
443 |
350 |
290 |
300 |
242 |
250 |
155 |
132 |
131 |
110 |
| 658 |
355 |
600 |
315 |
658 |
500 |
540 |
450 |
344 |
350 |
290 |
300 |
195 |
160 |
155 |
132 |
| 745 |
400 |
658 |
355 |
745 |
600 |
590 |
500 |
400 |
400 |
344 |
350 |
242 |
200 |
195 |
160 |
| 880 |
500 |
745 |
400 |
880 |
650 |
678 |
600 |
490 |
500 |
400 |
400 |
290 |
250 |
242 |
200 |
| 990 |
560 |
880 |
500 |
990 |
700 |
780 |
650 |
560 |
550 |
490 |
500 |
344 |
315 |
290 |
250 |
| 1120 |
630 |
990 |
560 |
1120 |
800 |
890 |
700 |
630 |
650 |
560 |
550 |
400 |
400 |
344 |
315 |
| 1260 |
710 |
1120 |
630 |
1260 |
900 |
1050 |
800 |
730 |
750 |
630 |
650 |
490 |
500 |
400 |
400 |
| 1460 |
900 |
1260 |
710 |
1460 |
1100 |
1160 |
900 |
890 |
900 |
730 |
750 |
560 |
560 |
490 |
500 |
| 1700 |
1000 |
1460 |
800 |
1530 |
1250 |
1380 |
1100 |
1060 |
1100 |
890 |
900 |
630 |
630 |
560 |
560 |
| |
|
|
|
|
|
|
|
1260 |
1300 |
1060 |
1100 |
730 |
710 |
630 |
630 |
| |
|
|
|
|
|
|
|
|
|
|
|
890 |
800 |
730 |
710 |
| |
|
|
|
|
|
|
|
|
|
|
|
1060 |
1000 |
890 |
800 |
| |
|
|
|
|
|
|
|
|
|
|
|
1260 |
1200 |
1060 |
1000 |
VLT Software Tools
For managing drive parameters in systems the new
VLT Motion Control Tool MCT 10 is the perfect tool
for handling drive related data. Improved from
previous VLT software dialogue tool, the MCT 10
offers:
- Project orientation one file that contains
all parameter settings and user defined
documents
- The Explorer like interface that is user
friendly
- SyncPos programming in the same environment,
one tool for all tasks
- On-line and off-line commission
- Support of different interfaces RS485,
RS232, USB and Profibus (with more to come)
- Import of drive settings from VLT software
tools
|